Shimadzu RS Nexera UHPLC for ultra low dispersion
System Dispersion in (U)HPLC is the reason why peaks can look ‘fatter’. This can effect resolution (separation of peaks) and the sensitivity (lowest limit of detection or quantitation). You can c...
-
Nexera UC (SFC) piping kits for Analytical SFC
Here are the piping kit options for installing the Nexera UC. Use the correct combination to support your bespoke installation. Nexera UC Piping Kits Remarks 228-61492-41 Piping Kit, basic ...
-
Changing the plunger seal to GFP for LC-2060
If you want to adjust the plunger seal of you Nexera-i system to GFP for greater number of litres of solvent. You can use the following part number. Note: the change in max. pressure 228-52711...
-
Upgrading LC-2050 to handle Hexane and Alkyl sulfonic acid with TFA
If you want your i Series to withstand aggressive non-polarised solvents such as Hexane or alkylsulfonic acid please upgrade the seal using the following part number for robustness. 228-32628-...
-
Adding a spacer kit for i Series (LC-2050 or LC-2060)
Adding a spacer kit for the i Series allows a divert valve to be positioned above and spaces the ELSD or MS away from the oven door. 228-62179-41 LC2030-LCMS Spacer Kit20 20This kit i...
-
Upgrading i Series (PDA) with Tungsten (W) bulb
Increasing the energy at higher wavelengths for LC-2050 or LC-2060 (3D) PDA systems. 228-57110-41 W Lamp for PDA, ASSY
-
Flow cell options for i Series (LC-2050 and LC-2060)
Flow Cell Options for i Series. NOTE: Path length reduced for some options. 228-56167-41 Conventional Cell for UV 228-45605-46 Semi-Micro Cell for UV 228-45621-41 High-speed cell for UV ...
-
Sample Loop options for i Series (LC-2050 and LC-2060)
Note: 50 uL loop for uHPLC options. 228-56074-44 Sample Loop (50 μL) 228-56074-42 Sample Loop (100 μL) 228-45405-41 Optional Loop (500 μL)6 228-45405-42 Optional Loop (2 mL)6 6max....
-
Adding a recycle valve to i Series LC-2050 or LC-2060
Note: Not for PDA options. If you would like to add a recycle valve to your UV detector on your i Series use the following part number. 228-56808-41 Recycle Valve
-
Installing a manual injector to an i Series
If you would like to install a manual injector to the LC-2050 or LC-2060 you can use this part number. 228-58790-41 Manual INJ Mounting Kit19 19This kit is used to fix a manual inject...