SCD furnace abs. press fell below lower limit [Error Code:6111]
The pressure of the furnace is low while the gas is flowing. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for p...
-
SCD furnace temperature set point not reached [Error Code:6106]
Although 90 minutes has elapsed after temperature control of the furnace started, the temperature does not reach the set value. Turn off the main power of the instrument, stop gas supply, ...
-
SCD furnace temperature controller error [Error Code:6105]
The temperature of the furnace does not increase even after [Heater] is set to [On]. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service rep...
-
SCD furnace temperature exceeds the limit [Error Code:6104]
The temperature of the furnace exceeds the upper limit of the specification. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representat...
-
SCD furnace temperature sensor error [Error Code:6103]
Measurement values on the temperature sensor of the furnace are unstable. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative...
-
SCD furnace temperature sensor is down [Error Code:6101]
The temperature sensor of the furnace is down and measurement cannot be conducted. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representa...
-
Untitled
The following causes are possible. Please check each item: Detector gas flow Press (HOME) - [Detector] to display [Detector] screen.Check that hydrogen gas, makeup gas, and air are supplie...
-
SCD hydrogen was overpressure[Error Code:6164]
Excessive hydrogen is supplied in the SCD detector since the hydrogen gas supply pressure is too high or the tubing is clogged. ・Check that the gas supply pressure is within the range below. ...
-
APCy set point not reached[Error Code:2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043]
The pressure or flow rate may have not reached the set value due to the following reasons.・The gas supply pressure is insufficient.・There is a leak at tubing connections.・The resistance of supply t...
-
DetAPCn air set point not reached[Error Code:2016 2019 2022 2025]
The pressure or flow rate may have not reached the set value due to the following reasons.・The gas supply pressure is insufficient.・There is a leak at tubing connections.・The resistance of supply t...