Prominence-i (UV) LC-2050
Advanced Prominence-i PLUS (iSeries) Part Number: 228-65820-58 Non-cooled Compact HPLC System 500 bar capability with 4 mobile phase lines (online blending) System / Gradient Delay Volume: 650 micr...
-
Low Temperature Analysis Kit for LC2050 and LC2060
If your application requires a lower column temperature this upgrade kit for the i-Series can allow you to set the column oven temperature 15 C below the room temperature e.g. if the room is at 20 ...
-
LabSolutions MD
"LabSolutions MD" streamlines a series of analytical method development work-flows from experimental design to design space construction, enabling non-experts to develop optimal analytical methods ...
-
LSSService error or Error [190b]
If a fatal software error is created by e.g. power outages / surges to IT infrastructure or critical software clashes; it may be required to perform the reinstallation of LabSolutions 5.xx (filebas...
-
What are the maximum pressure capabilities of Shimadzu LC systems?
If you want a quick guide to the pressure capabilities of the most popular Shimadzu systems, see below. Model / Brand Pressure Rating (bar) Comment Nexera - X3 1,300 UHPLC Nexera - XS or X...
-
HPLC Troubleshooting - High System Pressure
If you experience higher than normal system pressure; this may have been caused by one of the reasons below. Causes Solutions Flow rate set too high - Reduce flow rate setting. Use Smart ...
-
HPLC Troubleshooting - Fluctuating Pressure
If you notice your LC system is experiencing fluctuating pressure; the following causes may be responsible. Causes Solutions Air bubbles - Purge the solvent lines to remove the air bubble...
-
HPLC Troubleshooting - Low Pressure
If your LC system is demonstrating lower than expected system pressure; the following causes may be responsible. Causes Solutions Partial leak in system - Check all connections and retigh...
-
HPLC Troubleshooting - No Pressure Reading but, Flow is Nominal
If you observe no pressure on your system but, your pumping system is still working this may be caused by the following reasons. Causes Solutions Sensor malfunction - Repair or replace or ...
-
HPLC Troubleshooting - Noisy Baseline
If you observe a change in chromatography with a noisy baseline; some common causes are listed below. Causes Solutions Air in detector cell or pump - Degas mobile phase sufficiently and p...