(GCMS) EI Ion Source Replacement and Rinsing Procedure - GCMS-QP2010, PARVUM2/SE
For GCMS-QP2010 PARVUM2/SE Parts Number: 225-10446-91 EI ion source box Parts Number: 225-10442-91 EI repeller assembly Parts Number: 225-01068 BUSH FOR INSULATOR Parts Number: 085-35124-03 ABRA...
-
(GCMS) EI Ion Source Replacement and Rinsing Procedure - GCMS-QP2010 Plus/Ultra, QP2020,GCMS-TQ series
For GCMS-QP2010 Plus, GCMS-QP2010 Ultra, GCMS-QP2020,GCMS-TQ series Parts Number: 225-17697-91 BOX,EI+ (A P mark is engraved on the side of the box.) Parts Number: 225-31015-91 Smart EI/CI Ion S...
-
(GCMS) CI, NCI Ion Source Replacement and Rinsing Procedure - GCMS-QP2010
For GCMS-QP2010 Parts Number: 225-10617-91 CI ion source box Parts Number: 225-10617-92 NCI ion source box Parts Number: 225-10605-91 CI/NCI repeller assembly Parts Number: 225-01068 BUSH FOR IN...
-
(GCMS) CI, NCI Ion Source Replacement and Rinsing Procedure - GCMS-QP2010 Plus/Ultra, QP2020, GCMS-TQ series
For GCMS-QP2010 Plus, Ultra, GCMS-QP2020,GCMS-TQ series Parts Number: 225-17705-91 CI ion source box Parts Number: 225-17705-92 NCI ion source box Parts Number: 225-17710-91 CI/NCI repeller assembl...
-
(GCMS) Filament Replacement Procedure
Parts Number: 225-10340-91 FILAMENT D ASSY 0. Filaments are located at two places, at the top and the bottom. Top filament: filament #1 Bottom filament: filament #2 The following describes t...
-
CARm AFC PCB error [Error Code:11 12 53 54]
PCB may have failed. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement.
-
DET#1 2 3 4 PCB error [Error Code:7 8 9 10]
PCB may have failed. Turn off the main power of the instrument, stop gas supply, and contact your Shimadzu sales/service representative to ask for part replacement.
-
AOCn syringe counter error [Error Code:88 89]
The number of analysis exceeded the set threshold. Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer to the following for how to reset the counter value...
-
CARx insert counter error [Error Code:84 85 86 87]
The number of analysis exceeded the set threshold. Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer to the following for how to reset the counter value...
-
CARx septum counter error [Error Code:80 81 82 83]
The number of analysis exceeded the set threshold. Replace the consumables and then reset the counter on [Analysis Counter] screen. *Refer to the following for how to reset the counter val...